• Users Online: 161
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2017  |  Volume : 6  |  Issue : 2  |  Page : 38-42

Plateletpheresis adverse events in relation to donor and plateletpheresis session profile


Department of Transfusion Medicine, Government Medical College, Patiala, Punjab, India

Correspondence Address:
Rajni Bassi
12-A, Ranbir Marg, Model Town, Patiala - 147 001, Punjab
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijh.ijh_14_17

Rights and Permissions

Introduction: Increasing demand of platelet transfusions for patients has led to a trend in the increased use of automated blood collections. These share many of the same reactions and injuries seen with pooled platelets obtained from whole blood donation but also have unique complications. Aims And Objectives: To study the adverse events (AEs) of plateletpheresis procedure and their relationship with donor and plateletpheresis procedure session profiles. Materials And Methods: This is a retrospective observational study conducted from January 2016 to December 2016. A two-hundred and thirteen (213) plateletpheresis procedures were performed after taking informed and written consent from the donor. All the donors were male and selected according to the guidelines laid down by Director General of Health Services. The AEs were classified into donor related, kit/equipment related and technique related. Results: A total of 13 AEs were noted; of which, 8 (61.53 %) events were associated with donors, 3 (23.07 %) were owed to fault in kit/equipment and 2 (15.384 %) were due to technical aberrations. Donor related AEs included vascular injuries [n = 3 (1.40%)], vasovagal reactions [n = 2 (0.938%)] and perioral tingling sensation [n = 3 (1.40%)]. Technique related AEs [n = 2 (0.938%)] and kit/equipment related AEs [n = 3 (1.40%)] were due to faulty technique and defective kits respectively. Conclusion: Apheresis donations performed on cell separators are safe. Meticulous donor vigilance, superior technical personnel training and experienced transfusion medicine specialist's supervision will make donor's experience more pleasant.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed6645    
    Printed309    
    Emailed2    
    PDF Downloaded544    
    Comments [Add]    
    Cited by others 8    

Recommend this journal